Dishwasher Type Laboratory

share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Model CHN.GB/EURO/USA/AUS etc
Voltage 380V~/50Hz
Brand KingDa
Category Laboratory
Material Made according to relevant standards
Feature Customized according to technical agreement
Comm. method TCP/Rs232/Rs485/Wifi
产品详情

Specification model:


         Dishwasher performance testing laboratory can provide stable temperature and humidity environmental conditions for the dishwasher under test. It is also equipped with a constant temperature and pressure water system, a fully automatic water distribution system, and a software and hardware measurement and control system to provide a long-term stable Operating conditions under environmental and water quality conditions, test the energy consumption and other performance of dishwashers under relevant standards, and meet the testing requirements of national sampling, type testing, certification and accreditation of related products.




Design standards:


GB/T 20290-2016 Dishwasher energy efficiency and water efficiency limit values and grades

GB/T 23119-2017 Household and similar electrical appliances performance test water

EN 50242 Method for measuring the performance of household electric dishwashers

IEC 60436-2015 Household electric dishwasher performance measurement method

AS/NZS2007.1 Household Appliances Performance-Dishwasher-Performance, Energy and Water Consumption Test Method;

SASO 2692 Energy efficiency label requirements for household electric washing machines, etc.


System test items


1) Washing performance test;

2) Drying performance test;

3) Power consumption, water consumption and time (energy consumption and water consumption test);

4) Mechanical safety test;

5) Operational suitability test;

6) Program suitability test;

7) Life test;



Functional Overview:


    The laboratory is composed of test stations and reference machine stations. The energy and water use of the entire laboratory embodies the energy-saving design concept, realizes a high degree of automation, reduces manual participation, automatic water supply, does not require manual water replenishment, and the water tank is reasonably designed to avoid water quality. Adjustment repetition and waste; can automatically adjust the heating and cooling functions according to the use of the water tank, and the room temperature and humidity control is highly efficient and energy-saving; the whiteness meter test data is directly connected to the data system; the water tank softness and hardness are automatically adjusted without manual addition of reagents .




Control range and accuracy:


1. Air temperature range:

Performance room and pollution room: 18℃~25℃, ±0.5℃.

Performance room humidity: 45% RH ~90%RH, ±5% RH

2. Test water: equipped with pure water machine and automatic water dispenser:

Water temperature control: 5℃~65℃, ±0.3℃.

Water hardness control: various water supply pipelines such as pure water, standard soft water, standard medium hard water, standard hard water, and standard hard water can be provided;

Water pressure adjustment range: adjustable between 0.05-1.0MPa, fluctuation within the range of ±0.02MPa;

Flow control range: 0-12L/min;

Flow control accuracy: 0.1L.